The AELAB SK9600 Hematology Analyzer is designed for routine clinical hematology testing, combining electrical resistance counting with SFT hemoglobin measurement for high-accuracy CBC analysis. The system integrates 3-part WBC differentiation, 24 parameters, and three color histograms to support comprehensive blood cell evaluation. Its low sample consumption, automated diluting, mixing, rinsing, and clog-clearing functions ensure reliable performance in continuous operation.
The SK9600 features an 8.4″ color touch screen and Windows-based operation with graphical control, allowing simultaneous display of measurement parameters and histograms. The instrument provides automatic sample probe cleaning, large-capacity data storage up to 100000 sample results, and multiple printing options.
The AELAB SK9600 is built around a double-channel measurement system with a dedicated Hemoglobin testing module. Its durable housing integrates an internal thermal-sensitive printer, optional external printer support, and protected probe architecture for stable long-term operation. The 8.4″ touch display and Windows interface enable direct control using graphical buttons, mouse, or keyboard. The system includes automated internal and external probe cleaning to maintain accuracy and reduce maintenance.
The analyzer measures RBC, WBC, and PLT using electrical resistance principles, ensuring precise counting and sizing. Hemoglobin concentration is determined via the hemiglobincyanide and SFT methods. The SK9600 operates with venous, capillary, or prediluted samples, processing up to 60 tests per hour. Integrated data processing supports histogram generation for WBC, RBC, and PLT, along with full QC functions including X-B, L-J, SD, and CV %.
The SK9600 supports RS232 data transfer, keyboard input, and parallel printer connectivity. It integrates seamlessly into LIS environments and allows both internal and external print outputs. The Windows-based interface simplifies data review, result export, and record archiving.
| Model | Specifications |
|---|---|
| SK9600 | 3-part WBC differentiation, 24 parameters, 60 samples/hour, 8.4″ touch screen, 9.8 µL sample volume, 100000 result storage |
The AELAB SK9600 Hematology Analyzer is suitable for routine CBC testing in clinical laboratories, hospitals, veterinary clinics, research institutions, and screening centers. Typical applications include quantitative evaluation of RBC, WBC, PLT, hemoglobin, and related hematological indices for diagnostic assessment, treatment monitoring, and health screening.
The SK9600 is manufactured under strict AELAB quality control protocols and adheres to ISO and CE requirements for diagnostic laboratory instruments. Comprehensive QC modes support traceability and ensure reproducible analytical performance.
Specifications :
| Category | Details |
|---|---|
| Methodology | Electrical resistance for counting; hemiglobincyanide method and SFT method for hemoglobin |
| Parameters | 3-part differentiation of WBC; 21 parameters and 3 color histograms (WBC, RBC, PLT) |
| Work Mode | Double channel + unique hemoglobin test system |
| Sample Volume | 9.8 μL for venous and capillary mode; 20 μL for prediluted mode |
| Throughput | >60 samples per hour; operable 24 hours/day; auto sleeping & waking-up functions |
| Storage Capacity | Up to 100,000 sample results including histograms; supports inquiry & history data management |
| Operation Language | English |
| QC Control | X-B, L-J, X, SD, CV% |
| Reference Value Settings | Male, Female, Children, Neonate |
| Input / Output | RS232, parallel printer, keyboard |
| Printing | Graphic thermal printer with various printing format; optional external printer |
| Operating Temperature | 18°C – 30°C; wet ≤ 10–90% |
| Power Supply | 220 V ± 22 VAC, 50 ± 1 Hz |
| Dimensions | 33 cm (L) × 38 cm (W) × 43 cm (H) |
| Weight | 20 kg |
| Category | Details |
|---|---|
| Methodology | Electrical resistance for counting; hemiglobincyanide method and SFT method for hemoglobin |
| Parameters | 3-part differentiation of WBC; 21 parameters and 3 color histograms (WBC, RBC, PLT) |
| Work Mode | Double channel + unique hemoglobin test system |
| Sample Volume | 9.8 μL for venous and capillary mode; 20 μL for prediluted mode |
| Throughput | >60 samples per hour; operable 24 hours/day; auto sleeping & waking-up functions |
| Storage Capacity | Up to 100,000 sample results including histograms; supports inquiry & history data management |
| Operation Language | English |
| QC Control | X-B, L-J, X, SD, CV% |
| Reference Value Settings | Male, Female, Children, Neonate |
| Input / Output | RS232, parallel printer, keyboard |
| Printing | Graphic thermal printer with various printing format; optional external printer |
| Operating Temperature | 18°C – 30°C; wet ≤ 10–90% |
| Power Supply | 220 V ± 22 VAC, 50 ± 1 Hz |
| Dimensions | 33 cm (L) × 38 cm (W) × 43 cm (H) |
| Weight | 20 kg |
Download catalog for:
Looking for specific lab equipment? Fill out the form below, and our team will get back to you with detailed information and a personalized quote.