info@aelabgroup.com
QR Code 1
QR Code 2

AELAB SK9600 Hematology Analyzer – 3-Part Differential Blood Cell Counter

The AELAB SK9600 Hematology Analyzer provides precise 3-part WBC differentiation and 24 blood parameters for routine clinical, research, and diagnostic workflows. With electrical resistance counting, SFT hemoglobin measurement, low sample consumption, and an 8.4" color touch screen, the system ensures accurate, stable, and high-throughput CBC testing up to 60 samples per hour.
Modles : SK Series
whatsapp Whatsapp

The AELAB SK9600 Hematology Analyzer is designed for routine clinical hematology testing, combining electrical resistance counting with SFT hemoglobin measurement for high-accuracy CBC analysis. The system integrates 3-part WBC differentiation, 24 parameters, and three color histograms to support comprehensive blood cell evaluation. Its low sample consumption, automated diluting, mixing, rinsing, and clog-clearing functions ensure reliable performance in continuous operation.

The SK9600 features an 8.4″ color touch screen and Windows-based operation with graphical control, allowing simultaneous display of measurement parameters and histograms. The instrument provides automatic sample probe cleaning, large-capacity data storage up to 100000 sample results, and multiple printing options.

 

⚙️ Design & Construction

The AELAB SK9600 is built around a double-channel measurement system with a dedicated Hemoglobin testing module. Its durable housing integrates an internal thermal-sensitive printer, optional external printer support, and protected probe architecture for stable long-term operation. The 8.4″ touch display and Windows interface enable direct control using graphical buttons, mouse, or keyboard. The system includes automated internal and external probe cleaning to maintain accuracy and reduce maintenance.

 

🔬 Working Principle / Testing Method

The analyzer measures RBC, WBC, and PLT using electrical resistance principles, ensuring precise counting and sizing. Hemoglobin concentration is determined via the hemiglobincyanide and SFT methods. The SK9600 operates with venous, capillary, or prediluted samples, processing up to 60 tests per hour. Integrated data processing supports histogram generation for WBC, RBC, and PLT, along with full QC functions including X-B, L-J, SD, and CV %.

 

💡 Key Advantages

  • Automated diluting, mixing, rinsing, and clog-clear processes for continuous workflow stability
  • Low sample consumption: 9.8 µL venous/capillary and 20 µL prediluted mode
  • Large onboard storage of 100000 results with histograms for long-term data management
  • 24-hour operability with automatic sleep/wake modes for energy efficiency
  • Optional external printing and flexible RS232 connectivity for laboratory integration
  • 3 color histograms to enhance diagnostic detail for WBC, RBC, and PLT populations
  • Comprehensive QC management supporting laboratory GLP requirements

 

🔗 Connectivity & Integration

The SK9600 supports RS232 data transfer, keyboard input, and parallel printer connectivity. It integrates seamlessly into LIS environments and allows both internal and external print outputs. The Windows-based interface simplifies data review, result export, and record archiving.

 

🧠 Model Insight

Model Specifications
SK9600 3-part WBC differentiation, 24 parameters, 60 samples/hour, 8.4″ touch screen, 9.8 µL sample volume, 100000 result storage

 

🧪 Testing Applications

The AELAB SK9600 Hematology Analyzer is suitable for routine CBC testing in clinical laboratories, hospitals, veterinary clinics, research institutions, and screening centers. Typical applications include quantitative evaluation of RBC, WBC, PLT, hemoglobin, and related hematological indices for diagnostic assessment, treatment monitoring, and health screening.

 

Compliance & Quality Assurance

The SK9600 is manufactured under strict AELAB quality control protocols and adheres to ISO and CE requirements for diagnostic laboratory instruments. Comprehensive QC modes support traceability and ensure reproducible analytical performance.

 

Specifications :

Category Details
Methodology Electrical resistance for counting; hemiglobincyanide method and SFT method for hemoglobin
Parameters 3-part differentiation of WBC; 21 parameters and 3 color histograms (WBC, RBC, PLT)
Work Mode Double channel + unique hemoglobin test system
Sample Volume 9.8 μL for venous and capillary mode; 20 μL for prediluted mode
Throughput >60 samples per hour; operable 24 hours/day; auto sleeping & waking-up functions
Storage Capacity Up to 100,000 sample results including histograms; supports inquiry & history data management
Operation Language English
QC Control X-B, L-J, X, SD, CV%
Reference Value Settings Male, Female, Children, Neonate
Input / Output RS232, parallel printer, keyboard
Printing Graphic thermal printer with various printing format; optional external printer
Operating Temperature 18°C – 30°C; wet ≤ 10–90%
Power Supply 220 V ± 22 VAC, 50 ± 1 Hz
Dimensions 33 cm (L) × 38 cm (W) × 43 cm (H)
Weight 20 kg
Category Details
Methodology Electrical resistance for counting; hemiglobincyanide method and SFT method for hemoglobin
Parameters 3-part differentiation of WBC; 21 parameters and 3 color histograms (WBC, RBC, PLT)
Work Mode Double channel + unique hemoglobin test system
Sample Volume 9.8 μL for venous and capillary mode; 20 μL for prediluted mode
Throughput >60 samples per hour; operable 24 hours/day; auto sleeping & waking-up functions
Storage Capacity Up to 100,000 sample results including histograms; supports inquiry & history data management
Operation Language English
QC Control X-B, L-J, X, SD, CV%
Reference Value Settings Male, Female, Children, Neonate
Input / Output RS232, parallel printer, keyboard
Printing Graphic thermal printer with various printing format; optional external printer
Operating Temperature 18°C – 30°C; wet ≤ 10–90%
Power Supply 220 V ± 22 VAC, 50 ± 1 Hz
Dimensions 33 cm (L) × 38 cm (W) × 43 cm (H)
Weight 20 kg

Frequently Asked Questions

1What testing applications is the AELAB SK9600 suitable for?
It is used for routine CBC analysis including WBC, RBC, PLT, hemoglobin, and histogram evaluation in clinical and research laboratories.
2What is the sample volume required?
The analyzer uses 9.8 µL for venous/capillary samples and 20 µL in prediluted mode.
3How many samples can the instrument process per hour?
The SK9600 processes more than 60 samples per hour.
4Does the SK9600 support QC management?
Yes, it includes X-B, L-J, SD, and CV % QC functions.
5Can data be exported or printed?
Yes, via RS232 output, internal thermal printer, and an optional external printer.

Looking for specific lab equipment? Fill out the form below, and our team will get back to you with detailed information and a personalized quote.

Request Quote: AELAB SK9600 Hematology Analyzer – 3-Part Differential Blood Cell Counter