info@aelabgroup.com
QR Code 1
QR Code 2

AELAB NANO-500 Micro Volume Spectrophotometer – High-Precision Biomolecule Analysis

The AELAB NANO-500 Micro Volume Spectrophotometer is designed for precise analysis of nucleic acids, proteins, and biomolecules using as little as 0.5 µl of sample. With its intuitive touch screen, rapid measurement time, and built-in cuvette holder, it combines efficiency, accuracy, and versatility for modern laboratories.

Modles : NANO-500
whatsapp Whatsapp

The MicroSpectrophotometer NANO-500 is an advanced instrument designed for precise measurement of nucleic acids, proteins, and other biomolecules in micro-volume samples. It offers enhanced accuracy and sensitivity, suitable for various applications in molecular biology and biochemistry. The NANO-500 features an intuitive touch screen interface, requires no external computer, and includes a built-in cuvette holder, allowing for flexible measurement options. Its compact design makes it ideal for labs with limited space, while its high-performance optics ensure reliable and reproducible results.

 

Features

  • 7-inch touched screen, Android system with friendly Ul design
  • Ouick detection (only takes time of 2-6s), no dilution needed
  • Auto-detection functionis available
  • No need to preheat instrument. measurements can be done upon turning on
  • Long life’s Xenon flash lamp, 10⁹ flashes
  • Good repeatability due to accurate pathlength control
  • Heating up to 37°C , stirring speed 100-900rpm for cuevette measurements
  • Only 0.5 ~ 2µl sample volume requested, which can be recycled after test, ideal for precious samplesRNA、protein,down to 0.5pg/ul (dsDNA High Sensitivity)
  • Fluorometer measurement, strong specificity, high sensitivity can make it detect low concentration samples like dsDNA、Olipo、RNA、protein,down to 0.5pg/µl (dsDNA High Sensitivity)
  • Built-in printer
  • Measurement results can be exported to U disc in format of Excel、 JPG

 

🔬 How It Works?

The NANO-500 utilizes high-performance optical technology to measure absorbance and fluorescence in micro-volume samples. Its Xenon flash lamp provides stable illumination, while the linear CMOS array detector ensures precise readings. Users simply place 0.5–2 µl of a sample directly on the pedestal or in a cuvette. The instrument calculates concentration and purity instantly—without dilution or preheating—making it fast and reliable for routine lab analysis.

 

💡 Advantages

  • Micro-Volume Efficiency: Requires as little as 0.5 µl of sample, minimizing waste.

  • High Sensitivity: Detects dsDNA down to 0.5 pg/µl with excellent repeatability.

  • Versatile Measurement: Supports nucleic acids, proteins, oligos, and other biomolecules.

  • Dual Operation Modes: Pedestal & cuvette for flexible applications.

  • User-Friendly Interface: 7-inch Android touch screen with intuitive UI.

  • Time-Saving: Results in less than 6 seconds, with no preheating required.

  • Long-Term Value: Xenon lamp lasts >10⁹ flashes, reducing maintenance needs.

  • Data Management: Export results to USB in Excel or JPG formats.

 

🔍 Recommended Models by Use Case

  • Educational Labs & Training Centers → Simple, fast, and durable for routine teaching.

  • Research & Molecular Biology Labs → High sensitivity for nucleic acids, RNA, and protein studies.

  • Pharma & QC Departments → Reliable performance and GMP suitability for quality testing.

  • Food & Environmental Labs → Versatile detection for biomolecules in applied sciences.

 

🧪 Ideal For

  • DNA, RNA, and protein quantification

  • Molecular biology and biochemistry research

  • Pharmaceutical quality control

  • Food safety and environmental testing

  • Clinical and academic research laboratories

 

Specifications :

Model NANO-500 
Absorbance Precision 0.002Abs (1mm WaveLength)
Detector 2048 -element linear CMOS array
Sample Volume 0.5µl~2µl, advice 2µl
Absorbance Accuracy ±1% (7.332 at 260nm)
Power Adaptor DC12V 4A
Wavelength Range 180~910nm
Measurement Time <6s
Power 48W
Wavelength Accuracy ±1nm
Path Length 0.03mm、0.05mm、0.1mm、0.2mm、1mm
DiDimension (W*D*H) 300*232*196mm
Spectral Resolution ≤1.5nm(FWHM @ Hg 253.7nm)
Light source / Life Xenon / Flashes >10⁹
Weight 3.8 kg
Absorbance Range 0.02~750 (260nm, egualsto 10mm Wavelength)
Concentration Range 2ng/µl dsDNA~37500ng/µl dsDNA
OD600 Absorbance Range 0~4.000Abs
Absorbance Stability [0,3) ≤ 0.5%, [3,4) ≤ 1.5%
Absorbance Repeatability [0,3) ≤ 0.5%, [3,4) ≤ 1.5%
Absorbance Accuracy [0,2) ≤ 0.005A, [2.3) ≤ 1%, [3,4) ≤ 2%
Heating up 37℃
Stirring speed 100-900rpm
Fluorometer Sample Volume 1-20µl
Measurement Time 3s
Concentration Range 0.01ng/µl-120ng/µl dsDNA HS

0.2ng/µl-2000ng/µl dsDNA BR

0.05ng/µl-240ng/µl Oligo

01mg/ml-20mg/ml proteinBR

Repeatability < 1.5%
orders of magnitude of concentration 5
Linear dynamic range R² ≥ 0.995
Light Source LED
Excitation wavelength 470/625 (Standard)

365/525 (Optional)

Emission wavelength 525/690 (Standard)

460/620 (Optional)

 

Model NANO-500 
Absorbance Precision 0.002Abs (1mm WaveLength)
Detector 2048 -element linear CMOS array
Sample Volume 0.5µl~2µl, advice 2µl
Absorbance Accuracy ±1% (7.332 at 260nm)
Power Adaptor DC12V 4A
Wavelength Range 180~910nm
Measurement Time <6s
Power 48W
Wavelength Accuracy ±1nm
Path Length 0.03mm、0.05mm、0.1mm、0.2mm、1mm
DiDimension (W*D*H) 300*232*196mm
Spectral Resolution ≤1.5nm(FWHM @ Hg 253.7nm)
Light source / Life Xenon / Flashes >10⁹
Weight 3.8 kg
Absorbance Range 0.02~750 (260nm, egualsto 10mm Wavelength)
Concentration Range 2ng/µl dsDNA~37500ng/µl dsDNA
OD600 Absorbance Range 0~4.000Abs
Absorbance Stability [0,3) ≤ 0.5%, [3,4) ≤ 1.5%
Absorbance Repeatability [0,3) ≤ 0.5%, [3,4) ≤ 1.5%
Absorbance Accuracy [0,2) ≤ 0.005A, [2.3) ≤ 1%, [3,4) ≤ 2%
Heating up 37℃
Stirring speed 100-900rpm
Fluorometer Sample Volume 1-20µl
Measurement Time 3s
Concentration Range 0.01ng/µl-120ng/µl dsDNA HS

0.2ng/µl-2000ng/µl dsDNA BR

0.05ng/µl-240ng/µl Oligo

01mg/ml-20mg/ml proteinBR

Repeatability < 1.5%
orders of magnitude of concentration 5
Linear dynamic range R² ≥ 0.995
Light Source LED
Excitation wavelength 470/625 (Standard)

365/525 (Optional)

Emission wavelength 525/690 (Standard)

460/620 (Optional)

 

Product Video:

Frequently Asked Questions

1How is calibration done?
Calibration is factory pre-calibrated and requires minimal user adjustment. Periodic checks ensure consistent accuracy.
2Is the device GMP compliant?
Yes, the NANO-500 is suitable for GMP-regulated environments with reliable performance and repeatability.
3How long is the warranty?
Standard manufacturer warranty covers 12 months. Extended service plans may be available.
4Can precious samples be recovered?
Yes, micro-volume samples (0.5–2 µl) can be recovered after measurement, preserving valuable materials.
5What about low concentration detection?
The built-in fluorometer allows detection down to 0.01 ng/µl dsDNA, ensuring accurate results for dilute samples.

Looking for specific lab equipment? Fill out the form below, and our team will get back to you with detailed information and a personalized quote.

Request Quote: AELAB NANO-500 Micro Volume Spectrophotometer – High-Precision Biomolecule Analysis