AELAB Nucleic Acid Purification System Auto-Pure10B/10BW/10BS/16A – Efficient Magnetic Bead Extraction

The AELAB Auto-Pure Nucleic Acid Purification System provides efficient extraction using magnetic bead technology. Available in multiple models—Auto-Pure10B, Auto-Pure10BW, Auto-Pure10BS, and Auto-Pure16A—each system supports high-throughput purification with minimal reagent loss, making it suitable for a wide range of research and diagnostic applications.

Modles : Auto-Pure10B、Auto-Pure10BW、Auto-Pure10BS、Auto-Pure16A
whatsapp Whatsapp

The Auto-Pure10B, Auto-Pure10BW, Auto-Pure10BS, and Auto-Pure16A are compact instruments for nucleic acid extraction and purification using a magnetic bead method. Built on the Auto-Pure20B and Auto-Pure32A platforms, the Auto-Pure10 series can process up to 10 samples simultaneously, with a maximum sample volume of 5 ml. The Auto-Pure10BS features a dry bath heating function, making it ideal for large sample extractions in the field. The Auto-Pure16A can handle up to 16 samples at once, with a maximum volume of 1 ml per sample, offering versatility for various laboratory applications.

 

Features:

Auto-Pure10B

  1. Purification of 10 samples in one run
  2. Processing volume of 50-5000ul with 6.5ml-tube stripsfor Auto-Pure10B

Auto-Pure10Bs (with dry bath)

  1. Purification of 10 samples in one run
  2. Processing volume of 50-5000ul with 6.5ml-tube stripsfor Auto-Pure10B

Auto-Pure10BW (without heating for lysis and elution)

  1. Purification of 10 samples in one run
  2. Processing volume of 50-5000ul with 6.5mi-tube stripsfor Auto-Pure10B

 Auto-Pure16A

  1. Purification of 16 samples in one run
  2. Processing volume of 10-1000ul with 2.2ml Deep Well96 plate

Instrument features

1.3.4 inch touch screen, easy to use.

  1. Temperature and protocols can be edited and savedaccording to different reagent requirements.
  2. Short operation time: 15~40min per run
  3. High yield of nucleic acid with low magnetic bead loss andgood repeatability of results.

5.UV disinfection, avoid cross contamination.

  1. Open system which can apply to different magnetic beadextraction reagent.

7.APP software (Android system) which can monitor the systemin real time through mobile device.

  1. Using the PC software, user operate easily the machine.
  2. Screw rod design which guarantee high operating accuracy;large guide rail design makes the structure more reliable.
  3. With QR code identification function, special reagent canbe recognized, no need to program or obtain protocols.
  4. Small volume, suitable for extraction on site.

 

✅ How It Works?

The Auto-Pure series uses a magnetic bead-based extraction method, where nucleic acids are bound to magnetic beads, washed, and eluted for high purity. The process involves four steps: lysis, binding, washing, and elution. With UV disinfection and advanced control systems, the devices minimize contamination risks, offering reliable and repeatable results.

 

✅ Advantages

  • Versatile Applications: Process up to 16 samples simultaneously with high accuracy and minimal reagent loss

  • User-Friendly Interface: Intuitive 3.4-inch touchscreen control, easy to operate for all users

  • High Purity: Achieves more than 95% collection efficiency, providing high-quality results for sensitive downstream applications

  • UV Contamination Prevention: Built-in UV light ensures that cross-contamination risks are minimized

  • Portable & Field-Ready: The Auto-Pure10BS features a dry bath heating function, making it ideal for large sample extractions in field settings

 

✅ Recommended Models by Use Case

  • Auto-Pure10B/10BW/10BS: Ideal for mid-sized labs and field researchers, offering efficient processing of up to 10 samples at once

  • Auto-Pure16A: Perfect for high-throughput laboratories that require processing up to 16 samples, especially useful in diagnostic and clinical research settings

 

✅ Ideal For

  • Research Labs: For high-quality nucleic acid extraction in molecular biology research

  • Diagnostic Labs: Reliable for diagnostic testing, ensuring high-purity samples for downstream applications

  • Field Research: Auto-Pure10BS with its dry bath heating is tailored for on-site sample processing in remote locations

Specifications :

Type Auto-Pure10B Auto-Pure10BW Auto-Pure10BS Auto-Pure16A
Throughput 1~10 1~10 1~10 1~16
Process volume 50~5000ul 50~5000μl 50~5000μl 50~1000μl
Collection off effciency >95% >95% >95% >95%
Magnetic rod number 10 10 10 16
Plate types 5ml tube strip 5ml tube strip 5ml tube strip 96 Deepwell plate
Purification accuracy 100 copy sample positive rate>95%
Stability CV<5%
Heating for lysis tube Ambient temperature~120℃
Heating for elution tube Ambient temperature~120℃
Operation 3.4 inch color touch screen
Extraction steps Lysis, binding, washing and elution
Storage Capacity more than 100 programs
Software APP software and PC software
Pollution Control UV light
Lighting Yes
Extension interface 4 standard USB port, built in SD card
Exhaust Fan
Power Supply 300W 300W 300W 300W
Dimensions 340×350×410mm 340×350×410mm 340×350×410mm 340×350×410mm
Weight 18Kg 18Kg 18.5Kg 18Kg

 

No. Code Description No. Code Description
01 AS-17110-00 Auto-Pure10B, AC120V/240V, 50/60Hz 05 AS-17031-01 96-Deepwell plate for Auto-Pure16A
02 AS-17120-00 Auto-Pure10BW, AC120V/240V, 50/60Hz 06 AS-17031-02 Magnetic rod'stip for Auto-Pure16A
03 AS-17130-00 Auto-Pure10BS, AC120V/240V, 50/60Hz 07 AS-17041-02 Magnetic rod'stip for Auto-Pure10B/10BW/10BS
04 AS-17140-00 Auto-Pure16A, AC120V/240V, 50/60Hz 08 AS-17051-01 Tube strips for Auto-Pure10B/10BW/10BS
Type Auto-Pure10B Auto-Pure10BW Auto-Pure10BS Auto-Pure16A
Throughput 1~10 1~10 1~10 1~16
Process volume 50~5000ul 50~5000μl 50~5000μl 50~1000μl
Collection off effciency >95% >95% >95% >95%
Magnetic rod number 10 10 10 16
Plate types 5ml tube strip 5ml tube strip 5ml tube strip 96 Deepwell plate
Purification accuracy 100 copy sample positive rate>95%
Stability CV<5%
Heating for lysis tube Ambient temperature~120℃
Heating for elution tube Ambient temperature~120℃
Operation 3.4 inch color touch screen
Extraction steps Lysis, binding, washing and elution
Storage Capacity more than 100 programs
Software APP software and PC software
Pollution Control UV light
Lighting Yes
Extension interface 4 standard USB port, built in SD card
Exhaust Fan
Power Supply 300W 300W 300W 300W
Dimensions 340×350×410mm 340×350×410mm 340×350×410mm 340×350×410mm
Weight 18Kg 18Kg 18.5Kg 18Kg

 

No. Code Description No. Code Description
01 AS-17110-00 Auto-Pure10B, AC120V/240V, 50/60Hz 05 AS-17031-01 96-Deepwell plate for Auto-Pure16A
02 AS-17120-00 Auto-Pure10BW, AC120V/240V, 50/60Hz 06 AS-17031-02 Magnetic rod'stip for Auto-Pure16A
03 AS-17130-00 Auto-Pure10BS, AC120V/240V, 50/60Hz 07 AS-17041-02 Magnetic rod'stip for Auto-Pure10B/10BW/10BS
04 AS-17140-00 Auto-Pure16A, AC120V/240V, 50/60Hz 08 AS-17051-01 Tube strips for Auto-Pure10B/10BW/10BS

Frequently Asked Questions

1How does the Auto-Pure series maintain high sample purity?
The magnetic bead extraction technology combined with precise heating controls ensures high nucleic acid purity and recovery.
2Can the Auto-Pure system handle a variety of reagent types?
Yes, the Auto-Pure system is compatible with a wide range of magnetic bead extraction reagents, allowing flexibility for different applications.
3How long does it take to complete a nucleic acid extraction?
Extraction typically takes between 15 to 40 minutes, depending on the model and sample size.
4What makes the Auto-Pure16A different from the Auto-Pure10 series?
The Auto-Pure16A can process up to 16 samples at once and is designed for high-throughput applications with a smaller sample volume (50-1000µl per sample).

Looking for specific lab equipment? Fill out the form below, and our team will get back to you with detailed information and a personalized quote.

Request Quote: AELAB Nucleic Acid Purification System Auto-Pure10B/10BW/10BS/16A – Efficient Magnetic Bead Extraction