The AELAB SNB-T Series Touch Screen Rotary Viscometer performs precise viscosity measurement using modern touch screen control for rapid, accurate fluid viscosity testing. The AELAB SNB-T Series rotary viscometer integrates a 5 inches large color touch screen, built-in test programs, and stable rotor speed control to quantify viscosity and related rheological parameters in laboratory and industrial quality control environments.
The AELAB SNB-T Series Touch Screen Rotary Viscometer is widely used for viscosity testing of fluids and materials under heating, high temperature, and melting conditions. Typical applications include paint, coatings, cosmetics, printing ink, paper pulp, food, oil, latex, starch, solvent-based adhesives, and biochemical products where viscosity stability and repeatability are required.
The AELAB SNB-T Series Touch Screen Rotary Viscometer uses a rigid benchtop structure with stable leveling support to maintain consistent rotor alignment during viscosity measurement. The SNB-T Series rotary viscometer is controlled through a 5 inches color touch screen that displays measurement parameters and working conditions in real time. The instrument is equipped with standard rotors 1#, 2#, 3#, 4#, and a 0# rotor for low viscosity testing.

The AELAB SNB-T Series Touch Screen Rotary Viscometer measures viscosity by rotating a calibrated rotor in the sample at a controlled speed (r/min) and calculating viscosity from the resistance torque generated by the fluid. The SNB-T Series rotary viscometer automatically scans and recommends the best combination of rotor and speed, enabling accurate viscosity measurement across the selected viscosity range. For kinematic viscosity display, the AELAB SNB-T Series requires sample density input to calculate kinematic viscosity from dynamic viscosity.
The AELAB SNB-T Series Touch Screen Rotary Viscometer is used for viscosity measurement and rheological monitoring in scientific, industrial, and diagnostic laboratories. Common viscosity testing applications include:

The AELAB SNB-T Series Touch Screen Rotary Viscometer is designed for laboratory-grade viscosity measurement with repeatable performance and traceable workflow documentation through stored programs, timing functions, and printed data outputs. The SNB-T Series rotary viscometer supports controlled viscosity testing under constant temperature conditions using optional thermostatic components, supporting consistent QC practice in industrial and laboratory environments.
For advanced viscosity measurement, the AELAB SNB-T Series Touch Screen Rotary Viscometer operates on wide working voltage 110 V / 60 Hz or 220 V / 50 Hz and maintains a compact bench footprint of 300 × 300 × 450 mm for space-efficient laboratory integration. Discover precision viscosity testing performance with AELAB SNB-T Series rotary viscometer models SNB-1T and SNB-2T — engineered for accurate fluid viscosity analysis.

Specifications :
| Model | SNB-1T | SNB-2T |
|---|---|---|
| Control/display mode | 5 inches color touch screen | |
| speed (r/min) | 0.3/0.6/1.5/3/6/12/30/60 | 0.1/0.3/0.6/1.5/3/6/12/30/60 |
| Measuring rangemPa.s | 1~2,000,000 | 1~6,000,000 |
| (Measuring 10 under low viscosity, equipped with 0 # rotor) | ||
| rotor | 1, 2, 3, 4#(standard)
0# rotor(standard) |
|
| Measurement error (Newtonian liquid) | ±2% | |
| Repetitive error (Newtonian liquid) | ±1% | |
| Timing function | standard | |
| Temperature measurement function | The standard temperature sensor interface temperature sensor (selected) | |
| Automatic scanning function | Automatic scanning and recommend the best combination of rotor and speed | |
| According to maximum measuring range | Combination of rotor and speed automatically according to the selected viscosity range can be measured | |
| Should show shear/shear rate | standard | |
| Automatic display kinematic viscosity | Need to input the density of the sample | |
| Self-built measurement program | Can save up to 30 groups (including the rotor, rotational speed, temperature, time, etc.) | |
| Save the measurement results | Can save up to 30 sets of data (including viscosity, temperature, rotating speed of rotor, and the shear rate, Shear stress, time, density, kinematic viscosity, etc.) | |
| Viscosity curve | Real-time display viscosity curve | |
| Data, curve can print (standard equipped with print interface, to choose and buy a printer) | ||
| Data output interface | standard | |
| Constant temperature parts | Option (viscometer constant temperature trough, thermostatic cup, etc.) | |
| Working power supply | Wide working voltage (110 v / 60 hz or 220 v / 50 hz) | |
| Overall dimensions | 300 × 300 × 450(mm) | |
| Model | SNB-1T | SNB-2T |
|---|---|---|
| Control/display mode | 5 inches color touch screen | |
| speed (r/min) | 0.3/0.6/1.5/3/6/12/30/60 | 0.1/0.3/0.6/1.5/3/6/12/30/60 |
| Measuring rangemPa.s | 1~2,000,000 | 1~6,000,000 |
| (Measuring 10 under low viscosity, equipped with 0 # rotor) | ||
| rotor | 1, 2, 3, 4#(standard)
0# rotor(standard) |
|
| Measurement error (Newtonian liquid) | ±2% | |
| Repetitive error (Newtonian liquid) | ±1% | |
| Timing function | standard | |
| Temperature measurement function | The standard temperature sensor interface temperature sensor (selected) | |
| Automatic scanning function | Automatic scanning and recommend the best combination of rotor and speed | |
| According to maximum measuring range | Combination of rotor and speed automatically according to the selected viscosity range can be measured | |
| Should show shear/shear rate | standard | |
| Automatic display kinematic viscosity | Need to input the density of the sample | |
| Self-built measurement program | Can save up to 30 groups (including the rotor, rotational speed, temperature, time, etc.) | |
| Save the measurement results | Can save up to 30 sets of data (including viscosity, temperature, rotating speed of rotor, and the shear rate, Shear stress, time, density, kinematic viscosity, etc.) | |
| Viscosity curve | Real-time display viscosity curve | |
| Data, curve can print (standard equipped with print interface, to choose and buy a printer) | ||
| Data output interface | standard | |
| Constant temperature parts | Option (viscometer constant temperature trough, thermostatic cup, etc.) | |
| Working power supply | Wide working voltage (110 v / 60 hz or 220 v / 50 hz) | |
| Overall dimensions | 300 × 300 × 450(mm) | |
No download files available for this product.