The AELAB ICP-7760HP offers rapid and accurate simultaneous multi-element detection with minimal sample use. Featuring full-spectrum direct reading and advanced signal optimization, it ensures high precision and reduced operational costs for research and industrial labs.
The ICP-7760HP offers fast, precise multi-element analysis with full-spectrum direct reading in minutes. It minimizes argon use, supports qualitative analysis without standards, and detects all elements with minimal sample. Advanced features include simultaneous signal collection for accuracy, motor-driven signal optimization, and real-time spectral monitoring for quick adjustments, ensuring efficient and reliable performance.
Product features
The ICP-7760HP employs high-resolution two-dimensional spectroscopic technology to analyze samples by exciting atoms with plasma and detecting emitted light wavelengths. The simultaneous signal collection captures all elements across the full spectrum in minutes. Motor-driven adjustments optimize light source position and observation height, while real-time spectral monitoring allows dynamic parameter tuning, ensuring precise, interference-free readings.
Ultra-fast multi-element analysis within minutes
Significantly reduces argon consumption and operational costs
Qualitative analysis without needing standard solutions
High spectral resolution minimizes interference and error
Stable light source with automated flow control for consistent results
Advanced CCD detector enhances sensitivity and accuracy for trace elements
Nitrogen purging protects optics and improves UV detection efficiency
Long-term instrument stability with minimal drift for reliable data over time
Educational Labs: Ideal for teaching advanced elemental analysis techniques
Research Centers: Perfect for rapid, precise trace element detection in complex samples
Quality Control Departments: Ensures fast and reliable compositional verification
Environmental Testing Labs: Efficient for multi-element water and soil analysis
Industrial Labs: Suitable for metallurgy, petroleum, chemical, and nuclear applications
Geology & Metallurgy
Rare Earth Element Separation
Pharmaceutical & Healthcare Analysis
Environmental & Biological Research
Oceanographic & Agricultural Studies
Petrochemical & Nuclear Industry Quality Checks
Specifications :
High resolution medium step spectroscopic system
The most widely used medium step two-dimensional spectroscopic technology is adopted, and the spectral resolution is 0.007nm @ 200nm. It can completely deal with the serious spectral interference in ICP spectrometer, greatly reduce the error caused by spectral interference, and meet the needs of detecting various complex samples. Covering the full spectrum range, it can flexibly select any analytical spectral line.effectively avoid spectral interference according to the interference,and reduce various tedious spectral correction operations.
Excellent light source stability
The key to the stability of the analysis data lies in the stability of the light source. The solid-state generator designed and developed with the patented RF signal source can also ensure stable output power when measuring various complex substrates through the real-time closed-loop control technology. All three channels of argon of lCP light source use high-precision MFC (mass flow controller), which isfully automatically adjusted by software to ensure that the source has high stability when the instrument runs for a long time.
CCD Megapixel Spill Prevention Scientific CCD
With a megapixel CCD, the pixel resolution is less than3pm, more spectral data can be collected in the spectral contour, and the qualitative and quantitative accuracy is greatly improved.ICP spectrum contains strong argon spectrum and strong light spectrum of major elements.The CCD adopts spill prevention design to effectively avoid the pollution of these strong signals to weak signals. Deep refrigeration technology is used to further reduce the dark current of the sensor, which can effectively improve the signal-to-noise ratio and greatly reduce the detection limit in trace analysis.
Full optical path nitrogen purging
Using inert gas to purge the monochromator, on the one hand, it reduces the absorption of ultraviolet spectrum by air, on the other hand, it can prevent the damage of CCD caused by condensation or frost caused by refrigeration. The purge gas flow can be adjusted freely, which can effectively shorten the purge time and save gas consumption.
Qualitative function
It is not necessary to prepare standard solution and establish a method to conduct rapid qualitative analysis for unknown samples.Under stable analvsis conditions,semi quantitative accuracy can be achieved.
The injection system has high stability and wideapplication range
The 12 roller high precision peristaltic pump is adopted for sample injection, with small pulse and high analysis precision.Various types of atomizers, atomizing chambers and torch tubes can be selected to meet the needs of analyzing various samples.
Excellent long-term stability
The monochromator adopts the internal cavity type integral constant temperature control, which greatly reduces the drift caused by ambient temperature fluctuations. In the process of testing operation, thereare no moving parts in the instrument, ensuring high qualitative and quantitative accuracy during long operation.
Scope of application
Geology, metallurgy, rare earth separation, rare earth magnetic materials, medicine and health, environment,biology, ocean, petroleum, chemical industry, nuclear industry, agriculture, water quality and other scientific fields are widely used.
High resolution medium step spectroscopic system
The most widely used medium step two-dimensional spectroscopic technology is adopted, and the spectral resolution is 0.007nm @ 200nm. It can completely deal with the serious spectral interference in ICP spectrometer, greatly reduce the error caused by spectral interference, and meet the needs of detecting various complex samples. Covering the full spectrum range, it can flexibly select any analytical spectral line.effectively avoid spectral interference according to the interference,and reduce various tedious spectral correction operations.
Excellent light source stability
The key to the stability of the analysis data lies in the stability of the light source. The solid-state generator designed and developed with the patented RF signal source can also ensure stable output power when measuring various complex substrates through the real-time closed-loop control technology. All three channels of argon of lCP light source use high-precision MFC (mass flow controller), which isfully automatically adjusted by software to ensure that the source has high stability when the instrument runs for a long time.
CCD Megapixel Spill Prevention Scientific CCD
With a megapixel CCD, the pixel resolution is less than3pm, more spectral data can be collected in the spectral contour, and the qualitative and quantitative accuracy is greatly improved.ICP spectrum contains strong argon spectrum and strong light spectrum of major elements.The CCD adopts spill prevention design to effectively avoid the pollution of these strong signals to weak signals. Deep refrigeration technology is used to further reduce the dark current of the sensor, which can effectively improve the signal-to-noise ratio and greatly reduce the detection limit in trace analysis.
Full optical path nitrogen purging
Using inert gas to purge the monochromator, on the one hand, it reduces the absorption of ultraviolet spectrum by air, on the other hand, it can prevent the damage of CCD caused by condensation or frost caused by refrigeration. The purge gas flow can be adjusted freely, which can effectively shorten the purge time and save gas consumption.
Qualitative function
It is not necessary to prepare standard solution and establish a method to conduct rapid qualitative analysis for unknown samples.Under stable analvsis conditions,semi quantitative accuracy can be achieved.
The injection system has high stability and wideapplication range
The 12 roller high precision peristaltic pump is adopted for sample injection, with small pulse and high analysis precision.Various types of atomizers, atomizing chambers and torch tubes can be selected to meet the needs of analyzing various samples.
Excellent long-term stability
The monochromator adopts the internal cavity type integral constant temperature control, which greatly reduces the drift caused by ambient temperature fluctuations. In the process of testing operation, thereare no moving parts in the instrument, ensuring high qualitative and quantitative accuracy during long operation.
Scope of application
Geology, metallurgy, rare earth separation, rare earth magnetic materials, medicine and health, environment,biology, ocean, petroleum, chemical industry, nuclear industry, agriculture, water quality and other scientific fields are widely used.
Download catalog for:
Looking for specific lab equipment? Fill out the form below, and our team will get back to you with detailed information and a personalized quote.