AELAB SOX606 Soxhlet Extraction Fat Analyzer – High-Accuracy Fat Content Extraction

The AELAB SOX606 Soxhlet Extraction Fat Analyzer performs precise fat content determination using an automated Soxhlet extraction method. It features rapid metal-block heating, 0.1–100% measuring range, and ≥85% solvent recovery for efficient analytical workflows. The system provides stable temperature control, 6-position batch processing, and enhanced safety through an in-built ether leak detection device.
Modles : SOX Series
whatsapp Whatsapp

The AELAB SOX606 Automatic Soxhlet Extractor is designed based on the Soxhlet extraction principle with weight-based determination of fat content. It provides five extraction methods to meet different customer demands. The metal heating module offers fast heating, stable performance, and low power consumption, while the system ensures full water-temperature access, precise flow control, and economical operation. An integrated ether leak detection device enhances experimental safety.

The SOX606 is widely used in agricultural, food, chemical, environmental, soil, and sludge laboratories for extracting soluble organic compounds and determining fat content with high reproducibility.

 

⚙️ Design & Construction

The AELAB SOX606 features a robust metal-block heating system engineered for rapid and uniform temperature distribution up to 300°C. Its vertical operational interface enhances ergonomics, while the extraction system integrates customized Glass and PTFE components to prevent impurity interference. The system incorporates a solvent recovery mechanism achieving ≥85% efficiency and a structural design optimized for safety, stability, and long-term laboratory use.

 

🔬 Working Principle / Testing Method

The instrument performs Soxhlet extraction by cycling solvent through the sample under precise temperature control to dissolve fat and soluble compounds. The SOX606 regulates heating, condensing, solvent flow, and extraction sequencing with high stability. Weight-based analysis ensures accurate fat content determination from 0.1–100%, with reproducibility at a relative error of 1%. Automated five-method operation enables standardized and repeatable analytical workflows.

 

💡 Key Advantages

  • High-precision temperature regulation with ±1°C accuracy across a broad 5°C–300°C range.
  • Automated five-method Soxhlet workflow supports different extraction strategies.
  • ≥85% solvent recovery reduces operating cost and ensures environmental compliance.
  • 6-sample batch processing increases throughput for routine laboratory analysis.
  • Integrated ether leak detection enhances safety during volatile solvent extraction.
  • Optimized heating module minimizes power consumption while improving extraction speed.
  • Preset reagent selections and one-click start/pause functions improve operational efficiency.

 

🔗 Connectivity & Integration

The SOX606 supports modern laboratory integration through digital temperature control, automated process regulation, and optional data output functions. It aligns with GLP workflows requiring traceable fat extraction data and stable long-term performance.

 

🧠 Model Insight

Model Specifications
SOX606 0.1–100% measuring range, Room temperature +5°C~300°C, 6pcs/batch, 150mL cup volume, ≥85% solvent recovery, 2.6KW power

 

🧪 Testing Applications

The AELAB SOX606 is suitable for fat extraction and soluble organic compound analysis in food and feed testing, agricultural product inspection, environmental soil/sludge studies, chemical material analysis, and research requiring precise Soxhlet extraction performance.

 

Compliance & Quality Assurance

The SOX606 is manufactured under strict AELAB quality protocols and supports ISO, CE, and GLP-aligned analytical workflows. All components undergo performance verification to ensure accurate fat content determination, reproducible extraction cycles, and long-term operational reliability.

Specifications :

Model SOX606
Temperature range Room temperature +5°C~300°C
Measuring range 0.1~100%
Temperature accuracy ±1°C
Reproducibility Relative error 1%
Sample weight 0.5~15g
Capacity per batch 6pcs/batch
Solvent cup volume 150mL
Solvent recovery ≥85%
Power supply 220VAC±10%, 50Hz
Power 2.6KW
Dimensions 650mm×380mm×720mm
Net Weight 50kg
Temperature range Room temperature +5°C~300°C
Model SOX606
Temperature range Room temperature +5°C~300°C
Measuring range 0.1~100%
Temperature accuracy ±1°C
Reproducibility Relative error 1%
Sample weight 0.5~15g
Capacity per batch 6pcs/batch
Solvent cup volume 150mL
Solvent recovery ≥85%
Power supply 220VAC±10%, 50Hz
Power 2.6KW
Dimensions 650mm×380mm×720mm
Net Weight 50kg
Temperature range Room temperature +5°C~300°C

Frequently Asked Questions

1How many samples can be processed at once?
The SOX606 supports 6pcs/batch for routine high-throughput analysis.
2What is the measuring range of the SOX606?
The instrument measures fat content from 0.1–100% with ±1°C temperature accuracy.
3Does the system include solvent recovery?
Yes, it includes a built-in solvent recovery system with ≥85% efficiency.
4What are the recommended operating conditions?
Reliable performance is maintained between Room temperature +5°C to 300°C under standard laboratory conditions.

Looking for specific lab equipment? Fill out the form below, and our team will get back to you with detailed information and a personalized quote.

Request Quote: AELAB SOX606 Soxhlet Extraction Fat Analyzer – High-Accuracy Fat Content Extraction