The AELAB TDL4-ZF PRP/CGF/Fat centrifuge is a multi-functional tabletop centrifuge designed to separate fat, PRP, PRF, and CGF using compatible PRP kits or tubes and interchangeable rotors. The AELAB TDL4-ZF centrifuge supports PRP workflow standardization with touch screen operation, preset PRP/PRF/CGF programs, and free-setting modes for daily laboratory and clinical preparation.
The AELAB TDL4-ZF tabletop PRP centrifuge integrates microprocessor control for speed, time, and temperature regulation, while safety protections (imbalance protection, lid-lock, and over-speed alarm with error code display) support reliable operation in cosmetic surgery, beauty salons, clinics, and laboratory environments where repeatable separation is required.
The AELAB TDL4-ZF PRP/CGF/Fat centrifuge is a compact tabletop centrifuge with a 7-inch touch screen panel for direct program selection and parameter control. The AELAB TDL4-ZF centrifuge chamber supports UV lamp sterilization and illumination linked to lid status, and the rotor system is designed to accept multiple swing rotors and adapters for PRP tubes and syringe formats.
The AELAB TDL4-ZF centrifuge performs centrifugal separation by regulating rotational speed (r/min) and relative centrifugal force (×g) to stratify blood- or fat-derived components by density. The AELAB TDL4-ZF PRP/CGF/Fat centrifuge uses microprocessor control to stabilize time and temperature setpoints during spinning, enabling controlled preparation of PRP, PRF, and CGF fractions when used with compatible tubes, syringes, and adapters specified in the rotor list.
The AELAB TDL4-ZF PRP/CGF/Fat centrifuge is operated via the integrated touch screen interface with microprocessor control for speed, time, and temperature regulation. The provided technical sheets do not specify data ports or software export functions for the AELAB TDL4-ZF centrifuge; confirm connectivity requirements before procurement.
| Parameter | TDL4-ZF (Sheet A) | TDL4-ZF (Sheet B) |
|---|---|---|
| Max Speed | 5000 r/min | 4000 r/min |
| Max RCF | 5220×g | 3050×g |
| Temperature Range | -20~+40 °C | -10°C~+35°C |
| Noise | ≤60 dB(A) | ≤50 dB(A) |
| Power Supply | AC110 & 220 V 50 Hz~60 Hz 10 A | AC220 V 50 Hz 10 A |
| Dimensions | 485×550×360 mm(L×W×H) | 485*550*360 mm(L*W*H) |
| Net Weight | 45 kg | Not stated |
The AELAB TDL4-ZF PRP/CGF/Fat centrifuge supports sample preparation workflows where controlled separation is required. Typical uses for the AELAB TDL4-ZF tabletop centrifuge include PRP and PRF preparation for clinical procedures, CGF fraction preparation, and fat separation workflows when used with the specified PRP tubes and syringe adapters. The AELAB TDL4-ZF centrifuge is designed for clinic-based preparation and laboratory support where repeatable time, speed, and temperature regulation contribute to process control.
The AELAB TDL4-ZF centrifuge is specified with microprocessor control, lid-lock protection, imbalance protection, and over-speed alarm with on-screen error code display to support operational safety and quality consistency. The provided materials do not state ISO, CE, or GLP certification identifiers for the AELAB TDL4-ZF PRP/CGF/Fat centrifuge; confirm compliance documentation, calibration traceability, and validation requirements with the official AELAB release package before regulated deployment.
The AELAB TDL4-ZF PRP/CGF/Fat centrifuge is a compact tabletop instrument engineered for controlled clinical separation using multi-rotor flexibility, touch screen operation, and temperature regulation within the stated ranges for PRP, PRF, CGF, and fat preparation workflows.


Specifications :
| Model | TDL4-ZF |
|---|---|
| Max Speed/ RCF | 5000 r/min /5220×g |
| No.1 Angle Rotor | 12×10 ml (Vacuum type PRP PRF CGF Tube) |
| No.2 Swing Rotor | 16×10/15 ml (Vacuum type PRP PRF CGF Tube) |
| No.3 Swing Rotor | 4×20/50 ml syringe |
| No.4 Swing Rotor | 4×60/30 ml PRO / PURE / Prolo30 PRP tube |
| No.5 Swing Rotor | 4×20 ml double syringe PRP tube |
| No.6 Swing Rotor | 4×15 ml Arhtex Double syringe |
| No.7 Swing Rotor | 4×20 ml DR PRP tube |
| Timer /TemperatureRange | 0~99 min / -20~+40 °C |
| Motor | Microprocessor Control, Frequency Conversion Motor |
| Noise | ≤60 dB(A) |
| Power Supply | AC110 & 220 V 50 Hz~60 Hz 10 A |
| Dimension/Net weight | 485×550×360 mm(L×W×H) / 45 kg |
| Model | TDL4-ZF |
|---|---|
| Max Speed | 4000 r/min |
| Max RCF | 3050×g |
| Rotor | No.1 Swing Rotor (SY20) 4×20 ml syringe (with bucket cap) |
| Rotor | No.2 Swing Rotor (PX60) 4×60/30 ml PRO PRP tube |
| Rotor | No.3 Swing Rotor (PX100) 4×20 ml ACP double syringe |
| Rotor | No.4 Swing Rotor (DR20) 4×20 ml DR PRP tube |
| Rotor | No.5 Swing Rotor (DS15) 4×15 ml Arhtex Double syringe (with bucket cap) |
| Rotor | No.6 Swing Rotor (DS20) 4×20 ml ACP double syringe (with bucket cap) |
| Temp Accuracy | ±1 °C |
| Temp Range | -10°C~+35°C |
| Timing Range | 1 sec~99 min 59 sec |
| Motor | Microprocessor & AC Motor |
| Noise | ≤60dB(A) |
| Power Supply | AC220 V 50 Hz 10 A |
| Dimension | 485*550*360 mm(L*W*H) |
| Model | TDL4-ZF |
|---|---|
| Max Speed/ RCF | 5000 r/min /5220×g |
| No.1 Angle Rotor | 12×10 ml (Vacuum type PRP PRF CGF Tube) |
| No.2 Swing Rotor | 16×10/15 ml (Vacuum type PRP PRF CGF Tube) |
| No.3 Swing Rotor | 4×20/50 ml syringe |
| No.4 Swing Rotor | 4×60/30 ml PRO / PURE / Prolo30 PRP tube |
| No.5 Swing Rotor | 4×20 ml double syringe PRP tube |
| No.6 Swing Rotor | 4×15 ml Arhtex Double syringe |
| No.7 Swing Rotor | 4×20 ml DR PRP tube |
| Timer /TemperatureRange | 0~99 min / -20~+40 °C |
| Motor | Microprocessor Control, Frequency Conversion Motor |
| Noise | ≤60 dB(A) |
| Power Supply | AC110 & 220 V 50 Hz~60 Hz 10 A |
| Dimension/Net weight | 485×550×360 mm(L×W×H) / 45 kg |
| Model | TDL4-ZF |
|---|---|
| Max Speed | 4000 r/min |
| Max RCF | 3050×g |
| Rotor | No.1 Swing Rotor (SY20) 4×20 ml syringe (with bucket cap) |
| Rotor | No.2 Swing Rotor (PX60) 4×60/30 ml PRO PRP tube |
| Rotor | No.3 Swing Rotor (PX100) 4×20 ml ACP double syringe |
| Rotor | No.4 Swing Rotor (DR20) 4×20 ml DR PRP tube |
| Rotor | No.5 Swing Rotor (DS15) 4×15 ml Arhtex Double syringe (with bucket cap) |
| Rotor | No.6 Swing Rotor (DS20) 4×20 ml ACP double syringe (with bucket cap) |
| Temp Accuracy | ±1 °C |
| Temp Range | -10°C~+35°C |
| Timing Range | 1 sec~99 min 59 sec |
| Motor | Microprocessor & AC Motor |
| Noise | ≤60dB(A) |
| Power Supply | AC220 V 50 Hz 10 A |
| Dimension | 485*550*360 mm(L*W*H) |