info@aelabgroup.com
QR Code 1
QR Code 2

AELAB UV Irradiance Meter LT34-UVA – Precise UV Light Measurement for Industrial & Medical Applications

The AELAB UV Irradiance Meter LT34-UVA is engineered for accurate and reliable ultraviolet light measurements in a variety of industrial, medical, and scientific applications. With strict spectrum and angle corrections, this device offers high precision and low power consumption, making it the perfect tool for UV-related operations in fields such as sterilization, lithography, and water treatment.

 
Modles : LT34-UVA、LT34-UVB、LT34-UVC、LT34-UVA340(UVA+UVB)、LT34-UVV395 (UVA+UVV)、LT34-UVV420、LT34-UV Full、LT34-UVA/B/ C/UVV
whatsapp Whatsapp

The UV Irradiance Meter is designed for accurate ultraviolet irradiance measurements in applications such as sterilization, lithography, UV lamps, water treatment, and various industrial and medical fields, including shoe and leather factories and breeding facilities.

The instrument features strict spectrum and angle characteristic correction, ensuring stable performance and wide applicability. It employs microcomputer technology for low power consumption and high precision, with a digital LCD display and backlight for ease of use.

A Hold function allows users to lock and record data conveniently, facilitating comparison and analysis. Additionally, the meter can connect to a computer via an optional USB cable, enhancing data management capabilities.

 

Features

The product has been corrected by strict spectrum and Anglecharacteristics, stable performance and strong applicability.The instrument is suitable for the measurement of ultravioletirradiance in sterilization, lithography, UV sterilization lamp,mosquito killing lamp water treatment, mosquito killing lamp,shoe factory, leather factory medical treatment, breeding and other fields.

  • The spectrum and Angle characteristics are strictly corrected, and the stability is good
  • Microcomputer technology, low power consumption, high precision
  • Digital LCD display, backlight operation
  • The number has a Hold function, Hold key, lock data, easy to record and compare
  • The instrument comes with USB cable can be directly connected to the computer USB interface (optional)

 

How It Works?

The AELAB UV Irradiance Meter LT34-UVA measures the intensity of ultraviolet radiation in various wavelengths. Using strict spectrum and angle corrections, it ensures that the readings are accurate and stable across different application fields. The meter employs microcomputer technology, allowing for low power consumption while maintaining high precision. With a digital LCD display, users can easily read measurements, and the Hold function ensures that data can be locked and analyzed later.

 

Advantages

  • High Precision & Stability: Thanks to strict spectrum and angle characteristic corrections, the LT34-UVA provides reliable measurements for consistent results.

  • Low Power Consumption: Powered by 1.5AAA batteries, the device operates efficiently, extending battery life and reducing operational costs.

  • Ease of Use: The digital LCD with backlight and Hold function make it simple to use, even in low-light conditions.

  • Versatile Applications: Ideal for industries such as sterilization, lithography, water treatment, and medical applications, making it highly adaptable to diverse needs.

  • Data Management: Optional USB connectivity allows for seamless data transfer to a computer, enhancing data management and reporting.

 

Recommended Models by Use Case

  • LT34-UVA: Best suited for sterilization and water treatment applications in various industries, including medical facilities and breeding environments

  • LT34-UVB & LT34-UVC: Ideal for lithography and advanced UV sterilization in laboratories and industrial setups

  • LT34-UVV395: Recommended for UV testing in shoe factories and leather manufacturing, focusing on UVA and UVV bands

 

Ideal For

  • Sterilization & Medical Use: Ensuring proper UV light exposure for sterilization and germicidal processes

  • Industrial Applications: Lithography, water treatment, and testing UV irradiance in manufacturing

  • Research & Development: Lab and research settings where UV measurement is essential for controlled experiments and processes

Specifications :

Model LT34-UVA LT34-UVB LT34-UVC LT34-UVA340

(UVA+UVB)

LT34-UVV395 (UVA+UVV) LT34-UVV420 LT34-UV Full LT34-UVA/B/ C/UVV
P e a k 365±5nm(Bottom width315-400) 297±5nm(Bottom width280-315) 254±5nm(Bottom width200-280) 340(290-390) 395(340-420) 420(395-445) 365(200-400) Ultraviolet multi band(315-400)(280-315)(200-280)(340-420)
Display LED
Screen Power measuring range 2.000mW/20.00mW/200.0mW/cm²
Measurement accuracy ±5 %
Resolution 0.1 mW/cm²
Standard line the line length is 1 meter, and the extension must be customized
Sampling time ≈ 0.5 seconds
Temperature 0-50℃(32-122℉)
Humidity Less than 80%RH
Weight ≈200g(including battery)
Size Host: 140x72x34 mm Sensor:59xφ58mm
Power Supply 1.5AAA*4 batteries
Standard Host, instruction manual, portable case
Optional Bluetooth adapter and software,RS-232
Model LT34-UVA LT34-UVB LT34-UVC LT34-UVA340

(UVA+UVB)

LT34-UVV395 (UVA+UVV) LT34-UVV420 LT34-UV Full LT34-UVA/B/ C/UVV
P e a k 365±5nm(Bottom width315-400) 297±5nm(Bottom width280-315) 254±5nm(Bottom width200-280) 340(290-390) 395(340-420) 420(395-445) 365(200-400) Ultraviolet multi band(315-400)(280-315)(200-280)(340-420)
Display LED
Screen Power measuring range 2.000mW/20.00mW/200.0mW/cm²
Measurement accuracy ±5 %
Resolution 0.1 mW/cm²
Standard line the line length is 1 meter, and the extension must be customized
Sampling time ≈ 0.5 seconds
Temperature 0-50℃(32-122℉)
Humidity Less than 80%RH
Weight ≈200g(including battery)
Size Host: 140x72x34 mm Sensor:59xφ58mm
Power Supply 1.5AAA*4 batteries
Standard Host, instruction manual, portable case
Optional Bluetooth adapter and software,RS-232

Frequently Asked Questions

1How does the AELAB UV Irradiance Meter achieve its accuracy?
The LT34-UVA uses strict spectrum and angle characteristic corrections, along with microcomputer technology for precise measurements. This ensures stable performance across various industries.
2Can the AELAB UV Irradiance Meter connect to a computer for data management?
Yes, the LT34-UVA can be connected to a computer via an optional USB cable, enabling efficient data management and easy analysis.
3Is the AELAB UV Irradiance Meter suitable for use in water treatment?
Absolutely. The device is ideal for water treatment applications, where precise UV measurement is required for effective disinfection processes.
4What power source does the AELAB UV Irradiance Meter use?
The meter is powered by four 1.5AAA batteries, ensuring portability and ease of use in any environment.

Looking for specific lab equipment? Fill out the form below, and our team will get back to you with detailed information and a personalized quote.

Request Quote: AELAB UV Irradiance Meter LT34-UVA – Precise UV Light Measurement for Industrial & Medical Applications