AELAB AE-LAI-D2 Anaerobic Workstation – Controlled Oxygen-Free Microbial Culturing

The AELAB AE-LAI-D2 Anaerobic Workstation provides an oxygen-free environment for cultivating anaerobic and microaerophilic microorganisms. With integrated CO₂, temperature, and humidity regulation, it ensures stable incubation conditions for clinical, pharmaceutical, and environmental microbiology research.
Modles : AE-LAI-D2
whatsapp Whatsapp

The AELAB AE-LAI-D2 Anaerobic Workstation is a fully integrated oxygen-free microbial incubation system designed for culturing anaerobic and microaerophilic organisms. It maintains precise control over temperature, CO₂, humidity, and gas composition, providing an ideal environment for clinical, pharmaceutical, and research applications that require strict anaerobic conditions. The workstation’s robust construction and intelligent automation make it suitable for continuous laboratory operation and regulated microbiological testing.

 

⚙ Design & Construction

The AE-LAI-D2 features a sealed Stainless Steel chamber with clear access ports and removable front cover for ergonomic handling and easy cleaning. The interior includes an automatic humidity control system, integrated UV sterilization, and a built-in power socket. The large touchscreen interface provides real-time readings of temperature, humidity, and oxygen concentration. Multiple protection systems guard against overpressure, low pressure, and temperature deviations, ensuring safe, consistent anaerobic operation.

 

🔬 Working Principle / Testing Method

The workstation establishes an anaerobic state through vacuum-assisted gas replacement using nitrogen, hydrogen, and carbon dioxide. A high-efficiency palladium catalyst removes residual oxygen to achieve <0.1% oxygen concentration. CO₂ concentration (0–20%) and humidity (50–90% RH) are automatically regulated to prevent desiccation of cultures. The system supports both anaerobic and micro-oxygen modes (0–10% oxygen), suitable for a wide range of microbial testing conditions. The sealed chamber maintains stable oxygen-free conditions for over 13 hours without additional gas input.

 

💡 Key Advantages

  • Integrated control of temperature, humidity, and CO₂ in one sealed workstation
  • Adjustable oxygen level (0–10%) for anaerobic and microaerophilic applications
  • Automatic gas replacement and real-time oxygen monitoring via touchscreen
  • High-efficiency palladium catalyst minimizes maintenance frequency
  • Oil bottle-style pressure relief prevents air leakage and ensures chamber stability
  • UV sterilization and internal power outlet for aseptic operations
  • Ergonomic glove ports and optional bare-hand operation system

 

🔗 Connectivity & Integration

The AE-LAI-D2 integrates automated gas path control with programmable oxygen, CO₂, and humidity settings. The touchscreen interface allows operators to configure atmospheric profiles for specific microbial protocols. Optional data export via USB supports traceable documentation for GLP-compliant laboratories.

 

🧠 Model Insight

The AELAB AE-LAI-D2 offers a large operation chamber (95 × 67 × 75 cm) with sample transfer capacity for up to 40 standard 90 mm Petri dishes. Designed for flexibility, it accommodates instruments inside the chamber, allowing manipulation and incubation without atmospheric exposure. Its all-304 Stainless Steel structure ensures durability and chemical resistance for intensive microbiological use.

 

🧪 Testing Applications

  • Cultivation and study of anaerobic bacteria
  • Microaerophilic organism incubation
  • Clinical pathogen isolation and antibiotic susceptibility testing
  • Biopharmaceutical research and microbial stability analysis
  • Food spoilage organism detection and gut microbiome studies

 

Compliance & Quality Assurance

The AELAB AE-LAI-D2 Anaerobic Workstation complies with international microbiology and biosafety equipment standards. Each unit is factory-calibrated, tested for leak integrity, and validated for oxygen concentration accuracy. The system’s GLP-compatible data management and automated atmospheric control make it suitable for accredited laboratories, hospitals, and production quality control facilities.

Specifications :

Feature Details
Model AE-LAI-D2
Time to Create Anaerobic State (Sample Chamber) <5 min
Time to Create Anaerobic State (Operation Chamber) <1 h
Anaerobic Environment Maintenance >13 h (without gas supply)
Temperature Range RT +3 – 60 °C
Temperature Stability ±0.3 °C
Temperature Uniformity ±1 °C
CO₂ Range 0–20 %
CO₂ Control Accuracy ±0.1 % (imported sensor)
Humidity Control Range 50–90 % RH
Humidity Fluctuation ±3 % RH
Power Rating 1500 W
Power Supply AC 220 V, 50 Hz (customizable)
Interior Chamber Size (W×D×H) 42 × 29 × 47.5 cm
Operation Chamber Size (W×D×H) 95 × 67 × 75 cm
Sampling Chamber Size (W×D×H) 40 × 30 × 32 cm
Construction All 304 Stainless Steel body
Package Size (W×D×H) 151 × 92 × 152 cm
Accessories UV lamp, palladium catalyst, power socket, latex gloves, pressure relief bottle
Feature Details
Model AE-LAI-D2
Time to Create Anaerobic State (Sample Chamber) <5 min
Time to Create Anaerobic State (Operation Chamber) <1 h
Anaerobic Environment Maintenance >13 h (without gas supply)
Temperature Range RT +3 – 60 °C
Temperature Stability ±0.3 °C
Temperature Uniformity ±1 °C
CO₂ Range 0–20 %
CO₂ Control Accuracy ±0.1 % (imported sensor)
Humidity Control Range 50–90 % RH
Humidity Fluctuation ±3 % RH
Power Rating 1500 W
Power Supply AC 220 V, 50 Hz (customizable)
Interior Chamber Size (W×D×H) 42 × 29 × 47.5 cm
Operation Chamber Size (W×D×H) 95 × 67 × 75 cm
Sampling Chamber Size (W×D×H) 40 × 30 × 32 cm
Construction All 304 Stainless Steel body
Package Size (W×D×H) 151 × 92 × 152 cm
Accessories UV lamp, palladium catalyst, power socket, latex gloves, pressure relief bottle

Frequently Asked Questions

1What is the function of the AELAB AE-LAI-D2 Anaerobic Workstation?
It provides a controlled oxygen-free environment for the cultivation and handling of anaerobic and microaerophilic microorganisms.
2How does the workstation maintain anaerobic conditions?
It uses vacuum-assisted gas replacement and a palladium catalyst to reduce oxygen concentration below 0.1%.
3What are the temperature and CO₂ control capabilities?
The AE-LAI-D2 regulates temperature from RT+3 to 60 °C and CO₂ concentration between 0–20% with ±0.1% accuracy.
4Can it be used for both anaerobic and microaerophilic cultures?
Yes, the workstation supports oxygen levels from 0–10% for flexible incubation conditions.
5How long can it maintain anaerobic conditions without gas supply?
Over 13 hours of stable oxygen-free operation.
6What safety features are included?
The system has pressure protection, power leakage safeguards, and over-temperature alarms.
7What materials are used in construction?
The chamber is made entirely of 304 Stainless Steel for corrosion resistance and easy cleaning.
8What are the main application areas?
Clinical microbiology, food safety, biopharmaceutical research, and environmental microbial testing.