AELAB HB120-S / HB120-SC / HB60-S Dry Bath Heater – Compact Digital Heating Block for Laboratories

The AELAB HB120-S / HB120-SC / HB60-S Dry Bath Heater Series provides precise digital temperature control for sample incubation, enzymatic reactions, and molecular workflows. Featuring stable aluminum heating blocks, uniform heat distribution, and selectable temperature programs, this compact system ensures reliable daily operation in research and diagnostic laboratories.
Modles : HB Series
whatsapp Whatsapp

The AELAB HB120-S / HB120-SC / HB60-S Dry Bath Heater Series delivers precise temperature control in a compact, low-profile digital format. Engineered for accuracy, durability, and user convenience, this system supports reliable sample incubation for research, diagnostics, and quality control laboratories.

The AELAB Dry Bath Heater uses high-precision aluminum heating blocks combined with a digital control system. Integrated temperature sensors regulate heat output uniformly, ensuring stable heating for tubes and vials during incubation, digestion, and reaction workflows.

 

⚙️ Design & Construction

The HB120-S / HB120-SC / HB60-S models feature a rugged low-profile housing, precision-machined aluminum heating blocks, and a digital LED interface for fast temperature setting. The HB120-SC model incorporates an inbuilt temperature calibration function for enhanced accuracy. All units operate on 110/220 V, 50/60 Hz and support long-term stable heating for molecular and biochemical workflows.

 

🔬 Working Principle / Testing Method

The heaters elevate the aluminum block temperature to the selected setpoint through closed-loop digital control. Sensors continuously measure block temperature and adjust heating power to maintain uniformity across all wells. This ensures reproducible thermal conditions for enzymes, nucleic acids, and reaction mixtures.

 

💡 Key Advantages

  • Stable and uniform block heating with ±0.5 °C accuracy across HB120-S/SC
  • Preset discrete temperature levels for rapid workflows in HB60-S
  • Digital time control up to 99 h 59 min for all models
  • Compact 175×290×85 mm footprint for space-limited laboratories
  • LED display for clear temperature and timer visibility
  • Optional calibration function in HB120-SC for high-precision laboratories
  • Efficient heat transfer through high-conductivity aluminum block

 

🔗 Connectivity & Integration

The HB120-S / HB120-SC / HB60-S models feature digital control electronics suitable for standard laboratory integration. Data entry is performed directly through the panel, and systems operate independently without needing external software. Units are compatible with standard GLP workflows and traceable calibration procedures (HB120-SC).

 

🧠 Model Insight

Model Specifications
HB120-S 15–120 °C range, ±0.5 °C accuracy, block size 175×290×85 mm, 170 W power
HB120-SC Same as HB120-S with additional built-in temperature calibration function
HB60-S Preset 25/30/37/45/60 °C levels, ±0.5 °C accuracy, 160 W, compact 175×290×85 mm

 

🧪 Testing Applications

  • Molecular biology and PCR sample incubation
  • Enzyme reactions and controlled digestion
  • Immunoassay preparation and diagnostic workflows
  • Chemical and biochemical heating steps
  • Food, pharmaceutical, and environmental sample processing

 

Compliance & Quality Assurance

All AELAB dry bath heaters are manufactured under strict quality control with CE-compliant electronics, ISO-aligned production standards, and calibration traceability to ensure reproducible laboratory performance.

 

Blocks

AELAB HB120-S / HB120-SC / HB60-S Dry Bath Heater

Specifications :

Specifications H100-Pro HB105-S1 HB105-S2 HB150-S1 HB150-S2 HB120-S/SC HB60-S
Temperature range[°C] Room temp+5-100 Room temp+5-105 Room temp+5-150 Room temp+5-120 Room temp+5-60
Temperature Setting range [°C] 0-100 25-105 25-150 15-120 5 gears:25, 30, 37,45,60
Temperature control accuracy[°C] ±0.5 25-90: ±0.3 90-105: ±0.6 25-90: ±0.3 90-150: ±0.6 ±0.5 ±0.5
Temperature uniformity@ 37°C[°C] ±0.5 ±0.2 ±0.2 ±0.5 ±0.3
Power [W] 200 HB105-S1:100 HB105-S2:200 HB150-S1:100 HB150-S2:200 170 160
Time setting range 0min–99h59min 0min–99h59min 0min–99h59min 0min–99h59min 0min–99h59min
External sensor Yes Yes
Display TFT LED LED LED LED
Voltage,Frequency 110/220V,50/60HZ 110/220V,50/60HZ 110/220V,50/60HZ 110/220V,50/60HZ 110/220V,50/60HZ
External Dimension[W×D×H] 200×235×120 290×210×120 290×210×120 175×290×85 175×290×85
Weight (kg) 7.3 3.2 3.2 3 2.5
Operating temperature[°C] 10-40 10-40 10-40 10-40 10-40
Operating humidity[% RH] <80 <80 <80 <80 <80
Specifications H100-Pro HB105-S1 HB105-S2 HB150-S1 HB150-S2 HB120-S/SC HB60-S
Temperature range[°C] Room temp+5-100 Room temp+5-105 Room temp+5-150 Room temp+5-120 Room temp+5-60
Temperature Setting range [°C] 0-100 25-105 25-150 15-120 5 gears:25, 30, 37,45,60
Temperature control accuracy[°C] ±0.5 25-90: ±0.3 90-105: ±0.6 25-90: ±0.3 90-150: ±0.6 ±0.5 ±0.5
Temperature uniformity@ 37°C[°C] ±0.5 ±0.2 ±0.2 ±0.5 ±0.3
Power [W] 200 HB105-S1:100 HB105-S2:200 HB150-S1:100 HB150-S2:200 170 160
Time setting range 0min–99h59min 0min–99h59min 0min–99h59min 0min–99h59min 0min–99h59min
External sensor Yes Yes
Display TFT LED LED LED LED
Voltage,Frequency 110/220V,50/60HZ 110/220V,50/60HZ 110/220V,50/60HZ 110/220V,50/60HZ 110/220V,50/60HZ
External Dimension[W×D×H] 200×235×120 290×210×120 290×210×120 175×290×85 175×290×85
Weight (kg) 7.3 3.2 3.2 3 2.5
Operating temperature[°C] 10-40 10-40 10-40 10-40 10-40
Operating humidity[% RH] <80 <80 <80 <80 <80

No download files available for this product.

Frequently Asked Questions

1What applications are the AELAB HB120-S / HB120-SC / HB60-S used for?
They support sample incubation, enzymatic reactions, PCR preparation, melting curves, and general molecular biology workflows.
2Does the HB120-SC model support calibration?
Yes. The HB120-SC includes a built-in temperature calibration function for maximum accuracy.
3What is the maximum heating temperature?
HB120-S/HB120-SC heat up to 120 °C, while HB60-S provides preset steps up to 60 °C.
4Can the heater operate continuously?
Yes. All models support long-duration heating with a timer range of 0–99 h 59 min.
5What environment is recommended for operation?
Stable use is ensured at 10–40 °C and humidity below 80% RH.