info@aelabgroup.com

AELAB TD6 / iTD6 Tabletop Low-Speed Large Capacity Centrifuge for Clinical Sample Separation

The AELAB TD6 / iTD6 Tabletop Low-Speed Large Capacity Centrifuge is designed for biological, clinical, and epidemic prevention laboratories requiring reliable separation of blood, plasma, and urine samples. This laboratory centrifuge integrates microprocessor control, stainless steel chamber construction, and multiple rotor configurations to ensure stable speed regulation, safety-interlocked operation, and reproducible centrifugal performance for routine diagnostic workflows.
Modles : TD6 , iTD6
whatsapp Whatsapp

The AELAB TD6 / iTD6 low-speed large capacity centrifuge performs stable centrifugal separation for biological, hospital, and epidemic prevention laboratories. This tabletop centrifuge is engineered to process blood, plasma, and urine samples using controlled rotational speed and safety-interlocked operation.

The AELAB TD6 / iTD6 laboratory centrifuge integrates a stainless steel chamber, full metal housing, and microprocessor regulation to ensure consistent centrifugal force, low operational noise, and extended duty cycles for routine clinical analysis.

 

⚙️ Design & Construction

The AELAB TD6 / iTD6 centrifuge features a Stainless Steel chamber enclosed in a full metal structural frame. The reinforced tabletop design stabilizes rotor motion at low speed, while integrated cooling fans regulate internal temperature during extended operation. Safety interlock mechanisms prevent lid opening during centrifugation.

 

🔬 Working Principle / Testing Method

The AELAB TD6 / iTD6 low-speed centrifuge separates samples by generating centrifugal force through controlled rotor rotation. Adjustable speed and time parameters allow laboratories to regulate relative centrifugal force for sedimentation of blood cells, plasma separation, and urine analysis under repeatable conditions.

 

💡 Key Advantages

  • Microprocessor-controlled speed regulation for consistent low-speed centrifugation
  • Multiple angle and swing rotors for flexible sample volume processing
  • Stainless Steel chamber ensures corrosion resistance and hygiene compliance
  • Speed imbalance sensor and over-speed protection enhance operational safety
  • Emergency lid lock release in case of power interruption
  • Low noise operation ≤60 dB(A) for clinical laboratory environments

 

🔗 Connectivity & Integration

The AELAB iTD6 centrifuge is equipped with USB connectivity for PC communication and data management. Digital and Touch LCD interfaces display speed, time, and RCF values clearly for GLP-aligned laboratory documentation.

 

🧠 Model Insight

Model Comparison – AELAB TD6 Series
Model Display Type Maximum Output Weight
TD6 Digital 6000 r/min 52 kg
iTD6 LCD / Touch LCD 5600 × g 52 kg

 

🧪 Testing Applications

The AELAB TD6 / iTD6 centrifuge is used for clinical diagnostics, biological research, hospital laboratories, epidemic prevention stations, pharmaceutical sample preparation, and routine laboratory centrifugation of blood, plasma, urine, and cell suspensions.

 

Compliance & Quality Assurance

The AELAB TD6 / iTD6 low-speed centrifuge is manufactured under ISO-aligned quality systems with CE-compliant electrical safety design. Each unit supports laboratory quality control through calibrated speed accuracy, safety interlocks, and traceable operational parameters suitable for GLP laboratory environments.

 

Specifications :

Technical Specifications – AELAB TD6 / iTD6 Low-Speed Centrifuge
Model TD6 iTD6
Display Digital/LCD Touch LCD
Max Speed 6000 r/min    5600 × g 6000 r/min    5600 × g
Speed Accuracy ±10 r/min
Time Range 0~99 min 59 s
Rotor No. Rotor Capacity Speed (r/min) / RCF (× g)
No.1 Angle Rotor 12 × 10 / 15 mL 6000 / 5600
No.2 Swing Rotor 32 × 10 / 15 mL 4200 / 3120
No.3 Swing Rotor 48 × 10 / 15 mL 4000 / 3020
No.4 Swing Rotor 72 × 2 / 5 mL 4000 / 3020
No.5 Swing Rotor 108 × 2 / 5 mL 4000 / 3040
No.6 Swing Rotor 4 × 250 mL 5000 / 3300
No.7 Swing Rotor 8 × 50 mL 4200 / 3120
No.8 Swing Rotor 4/8  × 100 mL 4200 / 3120
No.9 Swing Rotor 4 × 500 mL 4000 / 3580
No.10 Well Plates Rotor 2 × 2 × 96 holes 4000 / 2300
Timer Range 0~99 min
Noise ≤60 dB(A)
Power Supply AC 220 V & 110V 50Hz 6A
Dimension (L × W × H) 602 × 502 × 412 mm
Weight 52 kg

Note: Rotors can be customized.

Technical Specifications – AELAB TD6 / iTD6 Low-Speed Centrifuge
Model TD6 iTD6
Display Digital/LCD Touch LCD
Max Speed 6000 r/min    5600 × g 6000 r/min    5600 × g
Speed Accuracy ±10 r/min
Time Range 0~99 min 59 s
Rotor No. Rotor Capacity Speed (r/min) / RCF (× g)
No.1 Angle Rotor 12 × 10 / 15 mL 6000 / 5600
No.2 Swing Rotor 32 × 10 / 15 mL 4200 / 3120
No.3 Swing Rotor 48 × 10 / 15 mL 4000 / 3020
No.4 Swing Rotor 72 × 2 / 5 mL 4000 / 3020
No.5 Swing Rotor 108 × 2 / 5 mL 4000 / 3040
No.6 Swing Rotor 4 × 250 mL 5000 / 3300
No.7 Swing Rotor 8 × 50 mL 4200 / 3120
No.8 Swing Rotor 4/8  × 100 mL 4200 / 3120
No.9 Swing Rotor 4 × 500 mL 4000 / 3580
No.10 Well Plates Rotor 2 × 2 × 96 holes 4000 / 2300
Timer Range 0~99 min
Noise ≤60 dB(A)
Power Supply AC 220 V & 110V 50Hz 6A
Dimension (L × W × H) 602 × 502 × 412 mm
Weight 52 kg

Note: Rotors can be customized.

No download files available for this product.

Frequently Asked Questions

1What samples can the AELAB TD6 / iTD6 centrifuge process?
It is used for blood, plasma, urine, and biological sample separation in clinical and laboratory environments.
2What is the maximum operating speed?
TD6 operates up to 6000 r/min, while iTD6 provides centrifugal force up to 5600 × g.
3Does the centrifuge include safety protection?
Yes, it includes lid interlock, imbalance detection, over-speed protection, and emergency lid release.
4Can rotors be customized?
Yes, rotor configurations can be customized based on laboratory requirements.
5Is PC connectivity supported?
The iTD6 model supports USB connection for PC communication and data management.

Looking for specific lab equipment? Fill out the form below, and our team will get back to you with detailed information and a personalized quote.

Request Quote: AELAB TD6 / iTD6 Tabletop Low-Speed Large Capacity Centrifuge for Clinical Sample Separation